Skip to main content
Software · Guides · Dentrix Performance

Why Is Dentrix Slow? A Dental IT Troubleshooting Guide for Practices

It is 10:40, the hygienist in room three has been staring at a spinning cursor in the Patient Chart, the front desk says the Appointment Book "takes forever to change days", and someone has already suggested restarting the server. Before anyone does, spend five minutes finding out where the delay lives.

Dentrix is usually slow because of one layer, not the whole system: a single workstation, the network path, the Dentrix database server, a scheduled job such as a backup or scan, an imaging bridge, or a recent update. Four clues identify it: which computers are affected, which module is slow, what time it happens and what was changed recently.

This guide gives the office manager a way to narrow it down without making it worse: a fork table, a map of Dentrix modules, the time-of-day patterns that give causes away, the Dentrix 2026 requirements check, and a five-field ticket card to hand to whoever fixes it. The hardware figures come from Henry Schein One's "Dentrix System Requirements 2026" (published April 2026), read on 22 October 2026. Henry Schein One revises those figures over time, so check the current edition before buying hardware.

In this guide
  1. First question: is the problem local or shared?
  2. How do you trace a slow Dentrix office in five yes/no questions?
  3. Which Dentrix module is slow, and what does each one point to?
  4. Does the time of day point to a backup, a Windows update or a sleeping computer?
  5. Does your server still meet Dentrix's 2026 requirements?
  6. Dental IT Support vs General IT Support
  7. Separate Dentrix Slowness from Imaging Slowness
  8. What five details make a Dentrix slowness ticket fixable?
  9. Avoid the Five Most Common “Fixes” That Create More Risk
  10. Which quick checks are safe for staff, and which belong to IT?
  11. Is it time to replace the Dentrix server, or redesign the setup?
  12. Your Practice Needs Clear Technology Ownership
  13. What to ask your IT provider about Dentrix performance
  14. Frequently asked questions

First question: is the problem local or shared?

Compare an affected workstation with a known-good one at the same time, doing the same task. One-device slowness usually points toward local resources or its network path; simultaneous office-wide slowness points toward a shared dependency. If only some rooms are slow, look for what those rooms share.

That single comparison removes about half of the possible causes before anyone touches a setting. Do it like this: ask a colleague at a second computer to open the same patient in the same module while the slow computer is struggling. If the second computer is quick, the Dentrix database and the server are probably fine, and the cause sits with the first computer or the cable, port or wireless link it uses. If both are slow at the same moment, stop looking at workstations and start looking at what they have in common.

DENTRIX PERFORMANCE TRIAGE

Use the three questions below as the first pass. Each one names the layer to look at, not a fix. The fixes come later, once someone has evidence.

Is it happening on ONE PC only?

Likely causes: local resource bottlenecks, pending Windows updates, a bad wall port or switch port, a loose or damaged ethernet cable, or local drivers and add-ons such as a signature pad, printer driver or imaging sensor software.

Quick checks that do not change anything: is this computer on Wi-Fi while its neighbours are cabled? Has it been restarted this week? Is its drive close to full? Did it get new software or a new device recently? Henry Schein One's 2026 requirements list 8 GB of memory as the workstation minimum and 16 GB as recommended, with 20 GB free on SSD or NVMe storage for the install. A computer bought years ago for scheduling only may sit below that today.

Is it happening on MANY PCs together?

Likely causes: server or storage saturation, a switch or firewall under strain, or a scheduled job (backup, antivirus scan, large report, update) running during patient hours.

Quick checks: note the exact time it started and whether it ends at a predictable time. Ask whether anything runs on the server at that hour. Check whether the server is also being used as someone's desk computer: the Dentrix requirements say the server can double as a workstation, but its disk space, memory and network throughput should be evaluated so that response to the other workstations stays acceptable.

Is it slow only around IMAGING?

Likely causes: imaging storage on a busy or nearly full drive, outdated sensor or camera drivers, or a bridge between Dentrix and the imaging software that broke after one side updated.

Quick checks: is the Patient Chart fast until someone clicks into images? Is it one imaging program or all of them? Did the imaging software or Dentrix update recently? If imaging is the only slow part, the section on separating Dentrix slowness from imaging slowness below is your next stop.

Is it slow only in some rooms, or only on Wi-Fi?

When a group of computers is slow but the rest of the office is fine, the shared thing is usually a piece of network equipment: one switch, one wireless access point, or a cable run to one wing of the building. Henry Schein One's requirements say wireless networks are used at your own risk because of potential interference from X-ray machines and other devices, and that wireless needs professional installation and should be Wireless-AC or higher. A Dentrix operatory on Wi-Fi is a common reason one room feels slower than the room next door.

How do you trace a slow Dentrix office in five yes/no questions?

Ask five questions in order: does the slowness follow the computer or the person; is it every computer at once; is it one module; does it happen at a predictable time; did something change in the last two weeks. Each yes or no removes layers, so the answer you end on is the layer to investigate, not a guess.

Work through this with the person who sees the problem, ideally while it is happening. Nothing in the table changes a setting.

ForkAskIf yesIf no
ADoes it follow the computer? (The same user logs in at another computer and Dentrix is fine there.)The computer, its cable or Wi-Fi, its port, or local software. Go to the one-PC checks above.Go to B.
BDoes it follow the person? (That user is slow at any computer; colleagues are fine.)Their Windows profile, their Dentrix user settings or security rights, or a large view they open (a busy Appointment Book view, a long ledger). Tell IT it is user-specific.Go to C.
CIs it every computer at the same time?A shared layer: the Dentrix server, storage, switch or firewall, or a scheduled job. Note the start and end time, then go to D.Some rooms only: the switch, access point or cable run those rooms share.
DIs it one module or action only?Use the module map in the next section.Everything is slow everywhere: shared layer again; record the time pattern (E).
EDoes it happen at a predictable time, or did something change in the last two weeks?Match the time to backups, scans, updates or reports; match the change to updates, new devices or network work.Log three occurrences (time, computer, module) before anyone changes anything.

Two extra tests help when the answers are unclear. First, close Dentrix on the slow computer and open a large file from the shared drive or a busy web page. If that is slow too, the problem is the computer or its connection, not Dentrix. Second, if the slowness seems random, it usually is not; it only looks random until someone writes down three occurrences with times. The pattern is almost always in the timestamps.

Which Dentrix module is slow, and what does each one point to?

The slow module is a clue. Delays in one module usually come from the data or add-on that module uses, while delays in every module point back to the computer, network or server. Name the module and the exact action ("changing days in the Appointment Book", "posting a payment in the Ledger") rather than "Dentrix is slow".

The table below is a map, not a diagnosis. It tells the person fixing the problem where to look first.

Module or actionWhat staff noticeLayer to look at firstWorth checking
Appointment BookSlow to change days or views; slow to open on one computerWorkstation and its connection if one computer; server or network if allIs the slow computer on Wi-Fi? Does the slowness grow with a busy multi-provider view?
Family File and patient selectPauses when searching or selecting a patientNetwork path to the server, server loadDoes it happen on every computer at the same moment?
Patient ChartSlow to open, slow to post treatmentWorkstation resources, chart add-ons, imaging links that load with the chartFast for some patients and slow for others with many images?
LedgerSlow to open long histories or post paymentsServer load, storage, size of the account historySlow for every account, or only the longest ones?
Office Manager reportsReports take a long time; the office slows while they runServer and storage during the reportAre large reports run first thing or at midday on a full schedule?
Document CenterSlow to open scanned documents or attachmentsStorage location of documents, network path, free spaceIs the document storage drive nearly full?
Launching imaging from DentrixLong pause or freeze when opening imagesImaging bridge, imaging software version, imaging storageDid either program update recently? Is only one imaging program affected?
Login and first open of the daySlow first connection, disconnect messages after idleWorkstation power settings, network adapter power management, overnight updatesDid the computer sleep overnight? Did Windows install updates?

A short glossary for the conversation with your IT provider:

    • Dentrix server: the computer that acts as the Dentrix database server for all the workstations, as Henry Schein One defines it. Every workstation depends on it.
    • Workstation: any computer running Dentrix for staff, from the front desk to the operatories.
    • Bridge: the link that lets Dentrix open a patient in another program, such as imaging software, and pass the patient's details across.
    • Scheduled job: anything set to run at a fixed time, such as a backup, antivirus scan, Windows update or a long report.

Does the time of day point to a backup, a Windows update or a sleeping computer?

Match the clock to the cause. A slowdown that starts at the same minute each day lines up with a backup, scan or report. Trouble at opening lines up with sleep or overnight update settings. A bad day after an update night lines up with the update. Months of gradual decline line up with full drives or an undersized server.

First thing in the morning. If Dentrix is slow to open or shows disconnect messages after a computer has been idle, look at power settings. Henry Schein One's requirements say that to avoid disconnect error messages on computers left inactive for long periods, practices should disable the power management options on the network interface cards, or close Dentrix when not actively using it. Overnight Windows updates that finish installing when someone logs in can also make the first half hour feel slow.

At the same time every day. Write down the start and end times for three days. If they line up, ask your IT provider what is scheduled in that window: backups, full antivirus scans, update installs, large reports or database work. A backup or scan that copies or reads large amounts of data from the same drive Dentrix uses can compete with the patient day. The fix is usually a schedule change, not new hardware.

After a Windows update. Microsoft's documentation explains that Windows uses "active hours" (the period a device is expected to be in use) to decide when it can restart after updates, and that automatic restarts happen outside them. The default window may not match your office's day, and a computer that was asleep may finish updating at the wrong moment. If Dentrix was fine on Monday and slow on Tuesday, check the update history on the slow computers. NIST describes patching as preventive maintenance to be planned, so updates belong in a schedule your provider can show you.

After a Dentrix or imaging update. Note the version numbers before and after. If one workstation updated and others did not, or the server and workstations are on different versions, say so on the ticket. Henry Schein One also notes that requirements for third-party add-on products should be verified with that product's vendor, so an imaging or add-on update may bring its own requirements.

At month-end or statement time. Large reports, statements and batch work run at the end of the month can load the server for everyone. If slowness clusters around those days, run heavy reports outside patient hours.

Slowly worse over months. A practice that keeps adding patients, images and workstations to the same server eventually outgrows it, and its drives fill up. Henry Schein One recommends more than 10 percent free space on all physical drives for best performance, and says additional server memory may be required for more than 10 workstations. A practice that has added rooms since the server was bought should check both.

Does your server still meet Dentrix's 2026 requirements?

Check the server and workstations against Henry Schein One's April 2026 requirements: a 64-bit server with 16 GB of memory (more may be needed above 10 workstations), workstations with at least 8 GB (16 GB recommended), install space on SSD or NVMe, 1 Gbps networking and a supported Windows version. Falling short is a common cause of office-wide slowness.

Henry Schein One describes these as minimum standards and says requirements "can vary significantly depending on workload and other software being used". Exceeding the minimum may give better performance. Use the table as a floor, not a target. For the full Dentrix platform picture, including servers and upgrades, see our page on Dentrix IT support for dental practices. For requirements across platforms and how to upgrade safely, see dental software system requirements and safe upgrades.

ItemDentrix server (2026)Dentrix workstation (2026)What to check in your office
Operating systemWindows Server 2016, 2019, 2022 or 2025; Standard or DatacenterWindows 10 or 11Any Windows 10 computer: Henry Schein One says that after June 30, 2026 it no longer supports installing Dentrix on Windows 10
Memory16 GB; more may be required for more than 10 workstations8 GB minimum, 16 GB recommendedCount your workstations against the server's memory
Processor4 or more cores at 2.4 GHz; 9th gen Intel Core i7 9700 or AMD Ryzen 27004 or more cores at 2.4 GHz; 9th gen Intel Core i5 9400 or AMD Ryzen 2600Older processors in the oldest operatory computers
Install space60 GB free on SSD/NVMe20 GB free on SSD/NVMeServers or workstations still on spinning drives
Network1 Gbps1 GbpsOlder switches, cables or Wi-Fi links below that
Free spaceMore than 10 percent free on all physical drivesSameDrives holding images and documents

The notes under the table matter as much as the numbers:

    • Server editions. Windows Server Essentials (including the Essentials role) and Small Business are not supported, because of port conflicts with backups. Server Core installs are not supported either.
    • Terminal Services and Citrix. Thin-client setups such as Terminal Services and Citrix are not supported and should not be used with Dentrix.
    • Virtual machines. Dentrix has been tested on properly configured Hyper-V and VMware virtual machines, but Dentrix Customer Support does not assist with issues caused by misconfigured or malfunctioning virtual machine software. If your server is virtual, the person who built it owns that layer.
    • The server as a workstation. Allowed, with the caution above about evaluating disk, memory and network throughput.
    • Upgrades. Systems being upgraded from previous Dentrix versions should have at least 60 GB of free space.
    • Antivirus. Recommended on all computers, with the Dentrix program directory excluded as described in the Dentrix Resource Center, weighing the risk of each exclusion.

If the answer to two or more rows is "we don't know", that is a finding in itself: ask your IT provider for a written inventory. Keeping that inventory current is a routine part of good IT support for dentists, so it should not need to become a separate project.

Dental IT Support vs General IT Support

Any competent IT provider can fix printers, email and a firewall. Dentrix slowness asks for something narrower: knowing how Dentrix, its database server, imaging bridges and add-ons depend on each other, and testing the network and server before recommending hardware. The difference shows in the questions a provider asks first.

The table below turns the comparison into questions you can put to any provider, dental-focused or general. For the full comparison, read dental IT support vs general IT support.

Dental IT and general IT troubleshooting comparison

Troubleshooting areaWhat a provider should be able to show youQuestion to ask
Dentrix database slowdownMeasurements of server memory, storage and network load during the slow window, before any hardware quote"What did you measure, and when?"
Imaging bridge glitchesWhich bridge, which versions on each side, and whether the problem follows one workstation"Is this the bridge, the imaging software or the computer, and how do you know?"
HIPAA safeguardsWhich safeguards are in place on the Dentrix server and workstations (access control, encryption, logging, backups) and how they are checked; not a blanket label"Which safeguards cover the Dentrix server, and how often are they reviewed?"
Vendor finger-pointingA clear record of who owns the ticket and which evidence went to Dentrix support or the imaging vendor"Who owns this ticket until it is closed, and what will you send the software vendor?"

Separate Dentrix Slowness from Imaging Slowness

Imaging problems often look like Dentrix problems because staff open images from inside Dentrix. If the Patient Chart and Appointment Book are fast but opening or acquiring images is slow, the cause is usually the imaging software, its bridge, its storage or the sensor driver, not Dentrix itself.

To tell them apart, time three actions on the same computer: open a patient's chart, open that patient's images from Dentrix, and open the imaging program directly. If only the second and third are slow, the imaging side is the place to look. If only the second is slow, the bridge is the prime suspect. If all three are slow, go back to the computer and the network. Write the versions of Dentrix and the imaging software on the ticket, and note whether the problem started after either one updated. For the imaging side in depth, see troubleshooting dental imaging integrations.

Old Way (Friction)

  • An error appears during sensor capture or when opening images.

  • The software vendor says it is the driver; the imaging vendor blames the network; the network person says it is the software.

  • Nobody has the times, versions or screenshots, so each support desk starts from zero.

Result: bouncing back and forth while the operatory stays down.

New Way (One Owner for the Ticket)

  • One named person in your practice, or your IT provider, owns the ticket from first report to close.

  • The ticket carries the evidence from the start: times, workstation names, versions, screenshots and the most recent change.

  • Each vendor receives the same facts, and the owner records what each one changed.

Result: fewer repeated questions, a shorter path to the right desk, and a record if the problem comes back.

What five details make a Dentrix slowness ticket fixable?

A ticket is fixable when it says when it happened, on which computer, in which module and action, what was on screen, and what changed recently. Those five details let a technician match the problem to a scheduled job, a workstation, a server or an update, instead of asking the same questions twice.

Print this card and keep it at the front desk. Fill it in the moment someone says "Dentrix is slow".

The Dentrix slowness ticket card

FieldWhat to writeExample
1. WhenDate, start time, end time (or "still slow")Tue 21 Oct, 10:35, still slow at 10:50
2. WhereWorkstation name (the label on the computer, or the name in Windows) and roomOP3-PC, operatory 3
3. WhatModule and exact actionPatient Chart, posting completed treatment
4. ProofA screenshot or phone photo of any message, and how long the wait was"Not responding" for about 40 seconds
5. ChangeAnything new in the last two weeks: updates, new device, moved computer, network workNew signature pad installed Monday

Add two short lines if you can: who else is affected (one computer, one room, everyone) and what you already tried (restarted the workstation at 10:45, no change). Those two lines stop the next person repeating your steps.

Send the card to the right place. If the evidence points to the computer, network or server, it goes to your IT provider. If it points to a Dentrix error message or behaviour inside the program on a healthy computer, it may need Dentrix support too; your IT provider can tell you which, and the same card serves both.

Avoid the Five Most Common “Fixes” That Create More Risk

The quick fixes people reach for under pressure often hide the evidence or add a second problem. These five common actions often amplify operational damage, and each has a safer alternative:

  1. Rebooting the server repeatedly without collecting evidence. A restart can clear the symptom for a while but also clears what was happening at the time. Fill in the ticket card first; if a restart is needed, note the time.
  2. Upgrading Windows everywhere at once. Compatibility with Dentrix, sensors and bridges should be confirmed on one test computer first. Henry Schein One lists supported Windows versions, and add-on vendors publish their own.
  3. Disabling security tools to make the system faster. Turning antivirus off leaves computers that hold patient records unprotected. Microsoft notes that you usually don't need exclusions at all, and Henry Schein One points to specific Dentrix exclusions. Ask IT to check those are correct, centrally managed and documented.
  4. Replacing the server before measuring the network. A new server will not repair a bad switch, a failing cable, an operatory on weak Wi-Fi or a workstation driver problem. Measure first.
  5. Letting multiple vendors make changes simultaneously. If the imaging company, the phone company and the IT provider all change something on the same day, nobody knows which change helped or hurt. One change at a time, logged.

Which quick checks are safe for staff, and which belong to IT?

Staff can safely observe and record: compare two computers, restart the one slow workstation once, check whether it is on Wi-Fi, close unused programs and fill in the ticket card. Anything that changes the server, the database, security settings, updates or network equipment belongs to your IT provider.

Safe for staff during patient hoursLeave for IT
Compare the slow computer with a working one on the same taskRestarting the Dentrix server
Restart the one slow workstation once, and note the timeRunning database utilities, purges or repairs
Check whether the computer is on Wi-Fi or cable, and whether the cable is seatedChanging antivirus settings or exclusions
Close programs that are not needed on that computerInstalling or rolling back Windows, Dentrix or imaging updates
Note which module and action is slow, and photograph any messageMoving cables between switch ports, replacing switches or access points
Ask whether anyone else is slow right nowChanging backup or scan schedules
Fill in the ticket card and send itReinstalling Dentrix on a workstation

Database housekeeping, such as purging very old appointments, is sometimes suggested as a speed fix. Treat it as an IT-led change made after a verified backup, outside patient hours, and only after the hardware, network and schedule causes have been ruled out.

Is it time to replace the Dentrix server, or redesign the setup?

Consider replacing or redesigning when the evidence shows the server is consistently at its limits during normal patient hours, it falls below the 2026 requirements for your number of workstations, its operating system is reaching end of support, or slowness returns after scheduling and network fixes. A single bad week is not that evidence.

The signals to look for:

    • Measured load, not opinion. Memory, storage and processor use on the server are high during ordinary hours, not only during backups or reports.
    • Requirements gap. The server has less memory than the 2026 requirements for your workstation count, runs on spinning drives, or runs a Windows edition Dentrix does not support. Henry Schein One notes Windows Server 2016 support ended in 2022 and extended support continues until 1/12/2027.
    • Repeat incidents. The same pattern comes back after the schedule, network and workstation causes were fixed.
    • Growth. More workstations, more locations or heavier imaging than the server was sized for.

If two or more apply, it is time to plan rather than patch: a replacement server, a redesign of storage and networking, or a different hosting model. Weigh those options in replacing a dental server vs moving to the cloud. If you are still choosing a platform, Dentrix vs Open Dental for dental practices compares the two. Practices on Open Dental can use the sister guide to why Open Dental runs slowly, traced symptom by symptom.

Your Practice Needs Clear Technology Ownership

Slowness keeps coming back when nobody owns the whole chain: workstations, network, the Dentrix server, backups, security tools and the vendors around them. Clear ownership means one named party holds the inventory, the schedules, the change log and the ticket history, so a problem is traced once instead of rediscovered each time.

What that looks like in practice:

    • An inventory. Every workstation, its name, room, Windows version and memory; the server and its storage; switches and access points.
    • A schedule. When backups, scans and updates run, written down and kept outside patient hours.
    • A change log. Every update, new device and network change, with a date, so "what changed?" has an answer.
    • A ticket history. The cards from this guide, kept, so a repeat pattern is visible.

If you are comparing providers, these are Legend Networking's published facts. Legend supports the IT environment for Dentrix, Eaglesoft, Open Dental, Archy. Legend's service model: in-house engineers; no outsourced first-level triage. Legend provides 24/7 monitoring, and Legend's helpdesk is staffed 24/7 at 1-800-794-1588 (one general number). Legend's coverage: onsite dispatch by appointment across served dental markets; remote-first nationwide. Legend has served over 3,500 practices since 2004 and holds a 4.8 rating · 173 Google reviews. Legend's operations are led by Ian Lynch: 22 years in dental IT; oversees the NOC, onsite dispatch and client technology roadmaps.

What to ask your IT provider about Dentrix performance

Use these questions whether you are working with your current provider or choosing a new one. Good answers are specific and written down.

    1. When Dentrix is slow, what do you measure first, and can you show me the results for our last incident?
    1. Which of our workstations fall below Henry Schein One's 2026 workstation requirements, and which are still on Windows 10?
    1. How much memory does our Dentrix server have, how many workstations connect to it, and how much free space is on each drive?
    1. What runs on the server during patient hours (backups, scans, updates, reports), and can you move it?
    1. Are the Dentrix antivirus exclusions set as Henry Schein One describes, and who reviews them?
    1. Which computers are on Wi-Fi, and is any operatory running Dentrix over a wireless link?
    1. How do you test a Windows, Dentrix or imaging update before it reaches every computer?
    1. Who owns a ticket that involves Dentrix support or our imaging vendor, and what evidence do you send them?
    1. Is our server virtual? If so, who built it and who supports that layer?
    1. What would make you recommend replacing the server, and what evidence would you show me first?
Questions

Frequently asked questions

Why is Dentrix slow on only one computer?

That pattern usually points to the workstation itself, its network path, local drivers or add-ons. Compare it with a healthy workstation doing the same task, check whether it is on Wi-Fi, when it was last restarted and how full its drive is, and confirm it meets the 2026 workstation requirements before anyone changes the server.

Why is Dentrix slow on every computer?

Simultaneous office-wide slowness suggests a shared dependency: the Dentrix server, its storage, the switch or firewall, or a scheduled job such as a backup, scan or update. Record when it starts and stops for a few days. If the times line up with a schedule, the fix is often moving the job out of patient hours.

Can the network make Dentrix slow?

Yes. Every workstation talks to the Dentrix server over the network, so a failing cable, an overloaded switch, a weak wireless link or packet loss can slow the program. Henry Schein One lists 1 Gbps networking in its 2026 requirements and calls wireless use "at your own risk" because of interference. Test the network before replacing hardware.

Can backups slow Dentrix?

A poorly timed or resource-intensive backup can compete with Dentrix for the same server and storage. If slowness happens at the same time each day, compare that window with the backup, antivirus scan and update schedules. Moving heavy jobs outside patient hours usually helps, and Henry Schein One does not support Windows Server Essentials because of port conflicts with backups.

Why does Dentrix freeze or say "Not Responding"?

A freeze means Dentrix is waiting on something: the server, the network, a drive, an add-on or an imaging bridge. Note the module, the action and how long it lasted, and take a photo of the message. Freezes after a computer has been idle can come from network adapter power settings, which Henry Schein One recommends disabling.

How much RAM does Dentrix need?

Henry Schein One's April 2026 requirements list 16 GB of memory for the Dentrix server, with more possibly needed above 10 workstations, and 8 GB minimum for each workstation, with 16 GB recommended. These are minimums; the company notes needs vary with workload and other software. Imaging workstations may need more under their own vendor's requirements.

Does antivirus slow down Dentrix?

Antivirus that scans Dentrix files constantly can slow the program, but the answer is correct exclusions, not turning protection off. Henry Schein One recommends antivirus on all computers and points to its Resource Center for excluding the Dentrix program directory. Ask your IT provider to confirm the exclusions are set centrally, documented and reviewed.

Why did Dentrix get slow after a Windows update?

An update can change drivers, restart services or finish installing when a computer wakes up, and add-ons may need their own updates afterwards. Check the update history on the slow computers and whether all of them changed. Test updates on one computer first, and ask your provider to schedule installs outside your office's active hours.

Can Dentrix run over Wi-Fi?

It can, but Henry Schein One says wireless networks are used at your own risk because of potential interference from X-ray machines and other devices. It asks for professional installation and Wireless-AC or better. If one operatory is slower than the rest, check whether it is on Wi-Fi and try a cabled connection before replacing the computer.

Ian Lynch
About the author

Ian Lynch

Owner & Operator, Legend Networking

22 years in dental IT. Oversees the NOC, onsite dispatch and client technology roadmaps for practices nationwide.

  • Operations center

    Dallas, Texas

    Serving dental practices nationwide since 2004

  • NOC hours

    24/7 monitoring

    Helpdesk staffed 24/7 at 1-800-794-1588

  • Engineers

    In-house only

    No outsourced first-level dental IT triage

  • Onsite dispatch

    By appointment

    Technicians deployed across served dental markets

About Legend Networking
Your next step

Dentrix slow right now? Call first, then ask for a measured review

If Dentrix is slow during patient hours, fill in the five-field ticket card and call Legend's helpdesk, staffed 24/7 at 1-800-794-1588. If the slowness keeps coming back, ask for a Free Dental IT Assessment: written findings on your computers, software, network security, backups and performance, with prioritized recommendations, so the next fix is based on evidence.

Or call 800-794-1588

Free IT assessment

Tell us what you are running

Your information is secure and will never be shared.