Skip to main content
Regional · DENTAL OFFICE CONTINUITY · OKLAHOMA CITY, MOORE, EDMOND AND TULSA

Tornado Warnings, Hail and Ice Storms: An Oklahoma Dental Office Plan for a Damaged Building or a Dark Grid

Picture a spring afternoon in Moore: a tornado warning goes out while a hygienist has a patient reclined. Or late October 2020, when ice gave OG&E its largest storm-related outage count ever. Two very different days, needing two different plans.

How Legend works with Central Oklahoma practices is set out on our dental IT support in Oklahoma City page. This guide is the tornado, hail and ice-storm plan for Oklahoma dental offices: a table that sorts events by what is damaged, an after-the-all-clear checklist, a placement check for the server closet, an asset register you can start this week, a restart rule for rotating outages, and an operating sheet for a long ice outage. For the wider picture of both metros, from utilities to growth corridors, see the Oklahoma dental IT guide.

Four things to carry into the plan:

- Oklahoma weather can damage the building itself, so the plan has to cover the room the equipment sits in, not only the power feeding it.
- In February 2021 the regional grid ordered rotating outages in Oklahoma. Power that keeps coming back and going away calls for a rule about when to restart.
- A dated list of every device, with photos, is what lets you show what was lost and replace it in the right order.
- Ice outages here have lasted days. Remote scheduling and forwarded phones keep the practice reachable while the building is dark.

In this guide
  1. What gets damaged in an Oklahoma storm, and what should happen first?
  2. What should the front desk do when a tornado warning is issued?
  3. Where should the server and network equipment sit in an office that gets hail?
  4. What is an IT asset register, and why does it matter after hail or a tornado?
  5. What happened in Oklahoma's February 2021 rotating outages, and what should an office do differently?
  6. How do you find out whether your office is on OG&E, PSO, Edmond Electric or a cooperative?
  7. What does a multi-day Oklahoma ice outage ask of the front desk, day by day?
  8. Which devices should a battery unit carry through Oklahoma's flickers and rotations?
  9. What should be ready before a tornado or hail leaves the building unusable?
  10. Who should own an Oklahoma practice's storm plan?
  11. What to ask your IT provider before tornado and ice seasons
  12. Frequently asked questions
  13. The bottom line

What gets damaged in an Oklahoma storm, and what should happen first?

Five things can be damaged: the safety of the people inside, the room (water through a hail-damaged roof), the power for days at a time (ice), the power in repeated cycles (a grid emergency), or the whole building. Each one has a different first hour, and each depends on something set up weeks earlier. Table A pairs them.

The point of sorting by damage is that the same storm can do any of these. A spring supercell can send everyone to the shelter room, crack the roof membrane with hail and leave the power on. A February cold snap can leave the building untouched and the grid unable to keep up. Your front desk needs to know which row they are in, and the weather radio will not tell them.

Table A. What is damaged, what to do in the first hour, and what must already exist

What is damagedTypical Oklahoma causeFirst hourWhat must already exist
People at riskA tornado warning for your areaNothing IT-related until the warning has passed. Afterwards, save and close the practice software and note the time.A shelter plan the dentist owns. Clinical and safety decisions are not the IT provider's call.
The room (water)Hail or wind-driven rain through the roofIf it is safe, cut power to wet equipment only at the breaker or wall switch. Move nothing that is wet. Photograph everything before touching it.Gear raised off the floor, clear of roof drains. A photographed asset register.
Power, for daysAn ice storm (examples: October 2020 around Oklahoma City; December 2007 around Tulsa)Orderly shutdown on battery backup. Switch scheduling and phones to remote work.An offsite backup. MFA-protected remote access. Call forwarding written down step by step.
Power, in cyclesA grid emergency in extreme cold (example: February 15-16, 2021)Shut down once. Leave it off until the utility announces that rotations are over.A written restart rule everyone knows.
The buildingA direct tornado hit, a collapsed ceiling, a long-term closureRestore to a borrowed or temporary space.A tested offsite backup, a hardware list, and a named person who orders replacement equipment.

Read across any row and the pattern is the same: the first hour is short and simple because the last column was done in advance. If the last column is empty, the first hour becomes a scramble.

For an outside view of where your office stands against this table, request a Free Dental IT Assessment.

What should the front desk do when a tornado warning is issued?

Get people to shelter. The dentist decides whether and how to stop treatment, following the equipment maker's guidance for any device in use. The front desk's IT job during the warning is nothing at all. After the warning passes, the job is small: save and close the practice software, check what still has power, and write down what you see.

That is a deliberate order. A chart left open on a front-desk screen for twenty minutes costs nothing. A staff member who stays behind to close it could be hurt. No IT step outranks the shelter plan, and a good provider will tell you so.

A local detail helps here. The City of Oklahoma City's tornado guidance, published May 2, 2023, says the city has 182 outdoor warning sirens, that they are tested at noon on Saturdays unless severe weather threatens, and that "There is no all-clear signal." Outside that Saturday test, treat a siren as real. And since no siren tells you it is over, decide in advance who will declare the all-clear for your office and what source they will use: the warning's expiry on a weather alert app, a local broadcast, or your county's emergency notices. Moore and other cities in the metro run their own warning systems, so read the guidance for the city where your office sits.

Checklist B. After the all-clear: 10 IT checks in 10 minutes

Each check is a look, not a repair. Anyone on the team can do it.

    1. Lights and outlets. Which rooms have power and which do not? Write it down by room.
    1. The battery backup units. Is any unit beeping or showing it is on battery? That means wall power is off to it.
    1. The server or storage device. Are its lights on? Do not press its power button.
    1. The network closet. Is the firewall's light pattern the same as usual? Is anything wet or dripping nearby?
    1. The ceiling. Look for new stains, sagging tiles or drips above the server, front desk and imaging rooms.
    1. The front desk. Can one computer open the schedule? If not, note the error on screen.
    1. The internet. Can a front-desk computer open any website? If not, check whether the modem or fiber terminal has lights.
    1. The phones. Does a call to the main number from a cell phone ring at the desk?
    1. Imaging. Look at the panoramic or cone-beam room for water or debris. Do not power it on until the dentist and the maker's guidance say so.
    1. Photos. Photograph any damage, wet equipment and ceiling stains before anyone moves or cleans them, then send the notes and photos to your IT provider.

If the checks find nothing, carry on with the day. If any of them finds water, a dark room or a device that will not come up, the next sections apply.

Where should the server and network equipment sit in an office that gets hail?

Low and interior. Put the server, firewall, switch and modem in an interior closet with a door and some airflow, on a shelf or short rack off the floor. Keep them away from roof drains, skylights, rooftop HVAC units and the top of an exterior wall. Never put them in the ceiling. Roof water travels downward and sideways before it shows.

Hail is the reason this matters more in Oklahoma than in most states. The Oklahoma Insurance Department, citing Verisk data in a release dated June 29, 2026, said that "In 2025, severe hail impacted 20% or more of roofs in 16 states, with Oklahoma being the highest nationally at 64.7%." The same release said 49.7% of Oklahoma roofs were impacted by severe hail over the previous four years. A hailstone that bruises a roof membrane in April may not leak until the next heavy rain in May, and the leak tends to find the lowest point under the damage. If that point is a ceiling-mounted rack, the first sign may be a server that will not boot.

The worst case is the building itself. The Newcastle-Moore tornado of May 20, 2013 inflicted significant damage to the Moore Medical Center, according to the National Weather Service in Norman. Equipment placement cannot protect against that. Only a copy of the data stored somewhere else can, which is why the offsite backup appears in the last column of Table A three times.

Table C. Placement check for an Oklahoma dental suite

Where the equipment sits nowThe riskA better option
A closet directly under a roof drain or valleyWater collects and drips straight down after hail damageAn interior closet away from drains; ask the landlord where the roof drains are
A rack mounted in or above the ceilingOut of sight, first to get wet, hard to reach in a hurryA short floor rack or wall shelf at waist height in an interior closet
A cabinet under the front-desk counterClose to exterior glass, foot traffic and mop waterMove the server to the closet; keep only the desk's own computer there
Under a sink or beside a water heaterPlumbing leaks, plus storm waterAnywhere dry; this location is a problem with or without hail
An interior closet with a door, off the floorThe lowest risk of the five, if it has airflowKeep it; add a vent or small fan so the heat can escape

Two cautions. Closets need airflow, because a closed, hot closet shortens equipment life and can trigger shutdowns on a summer afternoon. The server shutdown mistakes to avoid cover what heat and improper shutdowns do to a server. And if you lease, the landlord decides about roof repairs and changes to the building; your job is to know where the drains are and to keep your own equipment out of the way.

What is an IT asset register, and why does it matter after hail or a tornado?

An IT asset register is a dated list of every device in the office, with the room it sits in, its make, model and serial number, its purchase date, a photo, and how urgently it would need replacing. After hail or a tornado, it shows what was in the room before the damage and lets you order replacements in the right order without guessing.

Most practices have pieces of this already: a warranty email here, a purchase receipt there, a sticker on the server. What they lack is one sheet, kept current, with photos taken before anything happened. That sheet is useful to two people after a storm. One is whoever handles the practice's insurance claim, together with the practice's insurance agent, who decides what documentation the policy needs; we do not give insurance advice, and the policy wording is what counts. The other is the IT provider, who needs to know what to order first.

Template D. IT asset register (one row per device)

DeviceRoomMake / modelSerialPurchase dateWarranty endPhoto taken (date)Replacement priority (1-3)Who orders it
ServerIT closet1
FirewallIT closet1
Front-desk PC 1Front desk1
Operatory 3 PCOp 32
Wi-Fi access pointHallway ceiling3

Copy the header into a spreadsheet, add one row per device, and store the file somewhere outside the building, such as a cloud folder the owner and office manager can both reach. A register that lives only on the server is lost along with the server.

Worked example: a 5-operatory office in Norman (example figures)

Walk the office with a phone and you will usually count something like this:

    • 5 operatory computers
    • 5 intraoral sensors
    • 1 computer that runs the panoramic or cone-beam unit
    • 3 front-desk computers
    • 1 server or storage device
    • 1 firewall
    • 1 network switch
    • 4 Wi-Fi access points
    • 1 modem or fiber terminal
    • 1 phone system base or controller

That is 23 rows. Battery backup units and printers can be added as you go, but start with these.

Priority 1 is whatever lets the practice open in any form. Here that means five rows: the server (or the cloud login that stands in for it), the firewall, the network switch, the internet modem or ONT, and one front-desk PC. Add one operatory computer and one sensor so that at least one chair can see patients, and priority 1 is 7 rows of 23. Priority 2 is the remaining front-desk and operatory computers. Priority 3 is everything that can wait a week, such as extra access points.

With two people, one photographing and one typing, the walk-through for an office this size takes about an afternoon. Redo the photos once a year and whenever equipment changes. Two dates are easy to remember in Oklahoma: once in February or March before tornado season, and once in October or November before ice season.

When an office has to replace priority-1 hardware, Legend quotes it separately: "Hardware procurement, major cabling projects and software licensing are quoted separately." The register means that quote can be written from a list, not from memory.

What happened in Oklahoma's February 2021 rotating outages, and what should an office do differently?

During the deep cold of February 15-16, 2021, the regional grid operator, the Southwest Power Pool, moved to Energy Emergency Alert Level 3, its highest emergency level, and OG&E and PSO cut power in rotation across Oklahoma, about an hour at a time per rotation. Power dropped, returned, then dropped again. The lesson for an office is to shut down once and stay down until rotations end.

The Southwest Power Pool is the grid operator that balances supply and demand across a 17-state region that includes Oklahoma. When supply cannot meet demand, it can direct member utilities to drop load in rotation so the whole system does not fail. In February 2021 that meant neighborhoods and businesses losing power for a period, getting it back, and then losing it again as the rotation moved around.

For a dental office, that pattern is harder on equipment than a single long outage. Each return of power invites someone to restart the server, the imaging computers and the front desk. Each new interruption can catch them mid-boot, mid-update or mid-database write. A battery backup unit that carried the first shutdown may not have recharged before the second. The restart vs power cycle guide for dental offices explains why a clean restart and a hard power cycle are different things; rotating outages turn every restart into a gamble on the next cycle.

Rule E. The restart rule for rotating outages

    1. Shut down once. When power fails and rotations have been announced, let the battery units carry the server and network gear to a clean shutdown. Turn off the operatory and imaging PCs by hand.
    1. Stay off. Leave everything off until the utility or the grid operator says rotations have ended, or until power has been steady for a period your IT provider sets in advance and writes into the plan.
    1. Restart in order. Internet modem or ONT → firewall → switch → server → practice software → front-desk PCs → operatory PCs → imaging PCs → phones.
    1. Write down what failed. Note any device that does not come back cleanly, with the time, and send the list to your IT provider before trying again.

Put Rule E on one page, tape a copy inside the server closet door, and give one to every person who might be first in the building. The rule only works if the person standing next to the server on a cold morning knows it exists.

A practical note on the "steady period" in step 2: nobody can promise how long rotations will last, and we do not try. That is why the rule ties the restart to an announcement or an agreed period, and not to a guess.

If you want help writing a restart rule and a shutdown order that fit your own equipment, the Free Dental IT Assessment is a good place to start that conversation.

How do you find out whether your office is on OG&E, PSO, Edmond Electric or a cooperative?

The monthly power bill names the company; tenants can get it from the landlord. OG&E covers most of the Oklahoma City metro and PSO most of the Tulsa area, while the City of Edmond owns its own electric utility and Oklahoma Electric Cooperative, based in Norman, serves parts of central Oklahoma. A suburb's name tells you nothing reliable.

The answer decides which outage map, which alert service and which restoration queue apply to you. In the first minutes of an outage, the front desk will reach for a phone and look up the outage map. Pick the wrong company's map and the office shows as fine while your suite sits dark, and minutes go by before anyone notices the mistake.

The four you are most likely to see:

    • OG&E. The investor-owned utility for most of the Oklahoma City metro. Its home page is oge.com.
    • PSO. Part of AEP, with its headquarters in Tulsa; it serves the Tulsa metro and other parts of the state. Its home page is psoklahoma.com.
    • Edmond Electric. The City of Edmond runs it, so an Edmond office may report outages to the city instead of OG&E. The bill settles it.
    • Oklahoma Electric Cooperative. A member-owned co-op based in Norman that serves parts of central Oklahoma, Cleveland County included. Other co-ops serve the outer edges of both metros.

Once you know:

    1. Put the company's name on the first line of the storm plan.
    1. Register the practice for outage texts or emails on a shared number or inbox. Alerts tied to one person's phone go quiet when that person is on vacation.
    1. Bookmark the company's home page on two phones (owner and office manager) and navigate to outages from there. We link only home pages, because outage-map addresses change.
    1. Treat every additional office as its own question. A group with one office in north Oklahoma City and another in Edmond can be on two different utilities.

Practices in Tulsa and Green Country face the same questions with PSO and a different storm history, including the December 2007 ice storm; our guide to Tulsa dental IT covers what changes there.

What does a multi-day Oklahoma ice outage ask of the front desk, day by day?

Shut down in order on day 0, forward the phones and message patients. From day 1, run scheduling, patient messages and insurance follow-up from home laptops with multifactor sign-in. By day 2, decide whether to see patients somewhere else. When power is back and steady, reopen with the restart rule. Table F lays out each day.

Oklahoma's ice storms are why this section is long. During the October 2020 storm, OG&E counted over 400,000 outages at its worst point, its largest storm-related total ever, and on November 6, 2020, Oklahoma Emergency Management still showed roughly 51,000 OG&E customers dark. Around Tulsa in December 2007, PSO's own later account put its metro peak near 226,000 customers (about 78% of its Tulsa-area base), with the bulk of restoration from December 11 through 18. Those are dated lessons, not forecasts. They show that an office here can be dark for more than a day or two, and that the plan has to keep the practice reachable while the building is closed.

Table F. Ice-outage operating sheet

DayWhat happensWho does itWhat must already be set up
Day 0 (power fails)Clean shutdown on battery; main line forwarded; one text or email to the day's patients; time notedOffice manager, or whoever is first inBattery units on the server and network gear; forwarding steps on paper; a patient messaging tool you can reach from outside
Day 1Home-based front desk: moving appointments, picking up forwarded calls, chasing insurance; owner sets the plan for the next two daysFront desk and office manager; owner decidesMFA-protected remote access each person has tried; one agreed message for patients
Day 2 and laterDecide whether to see urgent patients at another office or a colleague's practice; decide what, if anything, travelsOwner, with the IT providerA tested offsite backup; the asset register; a written agreement with the other location
ReopeningWait for steady power; follow the restart rule; check the backup lastOffice manager with the IT provider on the phoneRule E on the closet door; the IT provider's number on the plan

Worked example: three closed days in Edmond (example figures)

A 5-operatory office books about 40 patients a day. An ice storm closes it for three days, so roughly 120 appointments need moving. Split across three front-desk staff working from home, that is about 40 calls or messages each, spread over three days. With remote access to the schedule and a forwarded main line, that is a heavy but manageable few days. Without remote access, the same 120 patients find out the office is closed when they arrive at a dark building or call a number that rings out.

Two links help with the details. Ice can also snap the internet line while the power holds; the steps for that case are in our guide for when the office internet line is down. For the offsite copy that makes Day 2 possible, see Legend's backup and recovery service; backup protection is listed as "Backup protection from $39.99 per month (storage-dependent)". Practices in Cleveland County can see how dental IT support in Moore is arranged.

Which devices should a battery unit carry through Oklahoma's flickers and rotations?

Battery backup units are for short flickers and an orderly shutdown; they will not run a clinic through an ice storm, and in a rotation a unit drained by the first cut may not have recharged before the next. The server or NAS, the firewall, the network switch, the internet modem or ONT, the phone system and at least one front-desk PC each need one. Operatory computers usually benefit. Follow the maker's guidance for panoramic and cone-beam units, and keep laser printers off them.

Table G. Battery backup by device

DeviceOn battery backup?Why
Server or storage deviceYesIt holds the practice database and needs time to close it cleanly
Firewall, switch, modem or fiber terminalYesWithout them, nothing can reach the cloud, the server or the phones
Phone system base or controllerYesCalls keep ringing long enough to forward them
One front-desk computerYesSomeone can save work and see the schedule while shutting down
Operatory computersUsuallySaves the chart and image in progress during a flicker
Panoramic or cone-beam unitFollow the maker's guidanceMany have specific power requirements
Laser printersNoThey draw heavy bursts of power and can overload a unit

We do not give battery runtimes here, because they depend on the unit, its age and what is plugged into it. Have your installer size each unit, then test the units whenever you refresh the asset register (February or March, then October or November). A unit that has never been tested is a guess.

What should be ready before a tornado or hail leaves the building unusable?

Three things, all set up before the storm: a tested offsite backup, a current asset register and an agreed temporary space. A practice with them can plan its next steps the same day. A practice without them starts by finding out what was lost. No provider can honestly promise a recovery time.

Here is what each one involves:

    1. The offsite backup, tested. A copy of the practice database and images stored outside the building, restored at least once in the past quarter so you know it works. The dental disaster recovery plan covers how to structure it.
    1. The hardware list. The asset register's priority-1 rows are your shopping list. Without it, the first day is spent working out what the office had.
    1. A temporary space. Another office in a group, a colleague's practice after hours, or a short-term suite. Agree on it in writing before you need it, including who pays for what and how internet access will work there.

Moving into temporary space is a small relocation, with network, printers, phones and imaging to set up in a hurry. The dental office relocation IT checklist is the right list to start from, trimmed to what the first weeks need.

If you are planning a new build, this is the cheapest moment to design resilience in: an interior IT closet away from the roof drains, a second internet path, and power for the network on its own circuit. The ownership decisions that come before those choices are in our guide to IT for a new dental office in Edmond.

Who should own an Oklahoma practice's storm plan?

The owner decides, the office manager keeps it current, and the IT provider checks the technical parts. That means one named person for the shelter plan, one for the asset register and phone forwarding, and the IT provider for the battery backups, the offsite backup and the restart rule. Write the names on the plan.

If you are weighing who should support that last part, Legend's national page on dental IT support sets out how Legend works, and the list of the best dental IT companies is a starting point for comparing providers.

Legend Networking is headquartered in Dallas. Oklahoma is on Central time, like Dallas, so the helpdesk works the same clock as an Oklahoma practice. Calls go to one general number, 1-800-794-1588, and the helpdesk is staffed 24/7. Separately, Legend runs 24/7 monitoring, which is a different thing from someone answering the phone. In Legend's own published wording: "In-house engineers; no outsourced first-level triage" and "Onsite dispatch by appointment across served dental markets; remote-first nationwide." Day-to-day software and support issues are handled remotely; cabling, installations, equipment moves and new-office build-outs are scheduled onsite by appointment.

For background, Legend has served over 3,500 practices since 2004, and its Google profile shows 4.8 rating · 173 Google reviews. Ian Lynch, who writes these guides, is described on Legend's site as "22 years in dental IT; oversees the NOC, onsite dispatch and client technology roadmaps." Owners comparing a dental IT company in Oklahoma City will find the local scope set out on that page.

What to ask your IT provider before tornado and ice seasons

Ask these in February and again in October, and keep the answers with the plan.

  1. Who supplies our electricity, and do its outage alerts reach a number more than one person watches?
  2. Is anything we own under a roof drain, near a skylight or in a ceiling?
  3. When was our asset register last updated with photos, and where is the copy stored outside the building?
  4. What is our restart rule after rotating outages, and is it posted where the first person in will see it?
  5. Can each front-desk person reach the schedule and forwarded calls from home through MFA, and when did each of them last try it?
  6. Where does our offsite copy live, and what was the date of our last test restore?
  7. Which devices are on battery backup, and when were those units last tested?
  8. If the building were closed for a month, where would we see patients, and is that agreed in writing?
Questions

Frequently asked questions

What IT checks should the front desk make once a tornado warning has passed?

Ten quick looks, no repairs: which rooms have power, whether any battery unit is beeping, whether the server and firewall lights look normal, any new ceiling stains or drips above the equipment, whether one front-desk computer opens the schedule, whether the internet and main line work, and whether the imaging room is dry. Photograph damage before anyone moves it, then send the notes and photos to your IT provider.

Where should the server and network equipment sit in an Oklahoma office prone to hail and roof leaks?

In an interior closet with a door and some airflow, on a shelf or short rack off the floor. Keep it away from roof drains, skylights, rooftop HVAC units and the top of an exterior wall, and never in the ceiling. Hail damage often leaks weeks later, and water runs to the lowest point. Keep an offsite backup as well, because placement cannot protect against a direct hit.

What is an IT asset register, and why build one before hail or tornado season?

It is a dated list of every device in the office with its room, make, model, serial number, purchase date, a photo and a replacement priority. Built before a storm, it shows what was in the room before the damage and tells your IT provider what to order first. Store it outside the building and refresh the photos each February or March and October or November.

What happened in Oklahoma's February 2021 rotating outages, and what should an office do differently?

In the cold of February 15-16, 2021, the regional grid operator moved to Energy Emergency Alert Level 3 and OG&E and PSO cut power in rotation. Repeated off-and-on cycles are hard on servers and imaging PCs. Shut down once on battery, keep everything off until the utility announces the rotations are over, then bring things back starting with the network gear and the server, finishing with imaging and phones.

Oklahoma City's sirens give no all-clear, so who should declare it for a dental office?

Name one person in the storm plan, usually the office manager or the dentist, and agree the source they will use: the warning's expiry on a weather alert app, a local broadcast or your county's emergency notices. The City of Oklahoma City says its 182 outdoor sirens have no all-clear signal. Until that person says so, nobody leaves shelter to close charts or check the server.

How much rescheduling does a three-day ice closure put on an Oklahoma front desk?

In our example 5-operatory office booking about 40 patients a day, three closed days means roughly 120 appointments to move, or about 40 calls or messages for each of three front-desk staff. That is manageable only if each person can reach the schedule from home through multifactor sign-in and the main line is forwarded. Test both in October or November, before ice season.

What should be ready before a tornado or hail damage closes the building?

Three things: a tested offsite copy of the practice database and images, restored at least once in the past quarter; the asset register's priority-1 rows as a shopping list; and a temporary space agreed in writing, such as another office in the group or a colleague's practice after hours. With those, an owner can plan next steps the same day. No honest provider will promise a recovery time.

Will a battery backup unit carry a dental office through rotating outages?

No. A battery unit buys minutes for a clean shutdown of the server, firewall, switch, modem, phone system and one front-desk PC. In rotating outages like Oklahoma's in February 2021, a unit drained by the first cut may not have recharged before the next, so shut down once and stay off. Have an installer size each unit, and test the units every spring and fall.

What belongs on an Oklahoma dental office's February and October storm checklist?

In February or March, before tornado season, walk the shelter plan, name who declares the all-clear, check the ceiling above the equipment and refresh the asset register photos. In October or November, before ice season, test the battery units, have each person log in from home, forward the phones and back, and read the restart rule aloud. Update the plan whenever staff or equipment change.

The bottom line

Most of what this plan needs is set up on ordinary days in February and October. If you would like your equipment placement, battery backups, offsite backup, remote access and restart rule reviewed against this guide, whether your office is in Moore, Norman, Edmond, Yukon or Broken Arrow, you are welcome to request a Free Dental IT Assessment. You can also read how Legend approaches dental IT support for practices across the country.

Ian Lynch
About the author

Ian Lynch

Owner & Operator, Legend Networking

22 years in dental IT. Oversees the NOC, onsite dispatch and client technology roadmaps for practices nationwide.

  • Operations center

    Dallas, Texas

    Serving dental practices nationwide since 2004

  • NOC hours

    24/7 monitoring

    Helpdesk staffed 24/7 at 1-800-794-1588

  • Engineers

    In-house only

    No outsourced first-level dental IT triage

  • Onsite dispatch

    By appointment

    Technicians deployed across served dental markets

About Legend Networking
Your next step

Get your office ready before the next warning or ice storm

Tell us what you are running and we will review it with you.

Or call 1-800-794-1588

Free IT assessment

Tell us what you are running

Your information is secure and will never be shared.