Skip to main content
Regional · LIGHTNING & SURGE PROTECTION · ORLANDO

Lightning and Surge Protection for Orlando Dental Offices: Where Surges Get In and Who Fixes Each Layer

Picture a Thursday, 3:40 p.m., in July, at a practice off Osceola Parkway in Kissimmee: one close crack of thunder, and the front-desk phones lose dial tone. Two operatory PCs will not boot. The server in the closet is humming, but the switch beside it is dark.

Nothing visibly hit the building, and that is the usual pattern. The surge came in on a wire, not through the roof. This guide is for the owner, or the office manager standing in for the owner, who is looking at the damage from the last storm and wants three answers: how the surge got in, what else it reached, and who should fix which part so it does not happen again next July. It names the paths, maps each piece of dental equipment to its exposure, separates the electrician's work from the IT provider's, and ends with a triage table your team can use the next time the lights flicker.

In this guide
  1. How often does lightning threaten an office in Central Florida?
  2. How does a surge reach equipment that was never struck?
  3. Which equipment in a dental office is most exposed, and how should each be protected?
  4. Surge protector, UPS or whole-building protection: what's the difference?
  5. How long should the batteries last, and what should shut down first?
  6. What do Duke Energy Florida and OUC outages look like for an Orlando practice?
  7. What should the office do while a storm cell is overhead?
  8. After a strike, how do you find what was damaged?
  9. What does surge and power protection cost, and who pays for what?
  10. What to ask your IT provider about storms and surges
  11. Where the facts on this page come from
  12. Frequently asked questions
  13. The bottom line

How often does lightning threaten an office in Central Florida?

Often, and on a predictable clock. In NWS Melbourne's phrase, central Florida is the "Lightning Capital" of the United States, and over 90% of this area's lightning arrives from May to October, between noon and midnight. For a dental office, that lands on the afternoon schedule for half the year.

NWS Melbourne's lightning facts page (undated, accessed 19 October 2026) also names the band running from Tampa Bay across to Titusville "Lightning Alley" and says it gets more lightning each year than any other part of the country. Orlando sits between those two ends, so a practice in Winter Park, Sanford, Altamonte Springs, Clermont or Kissimmee is inside the corridor the weather service is describing.

The human toll comes first. An NWS-hosted compilation of NOAA Storm Data (Vaisala, updated May 2018) counts 498 lightning deaths in Florida from 1959 to 2017, the most of any state. NWS Melbourne adds that, on average, "lightning is responsible for more weather-related deaths in Florida than all other weather hazards combined." Staff and patient safety is the reason the office has a storm routine at all; the equipment comes second.

What the timing means for IT:

    • Summer afternoons carry the risk. If your practice runs a 7 a.m. start, most of the season's lightning falls after lunch, during the busiest restorative and hygiene blocks.
    • Planned work belongs in the morning. Server updates, firewall changes and imaging software upgrades scheduled for a June or August afternoon compete with storm cells. Ask for morning or weekend windows from May through October.
    • The off-season is for fixing. November through April is the time to replace UPS batteries, add data-line protection and have the electrician look at the panel, before the next wet season starts.

A practice does not need a direct strike to lose equipment. A strike on a pole down the street, on the cable plant or on a neighbouring building can push a surge through the wires your office shares with everyone else on the block. The next section follows those wires.

How does a surge reach equipment that was never struck?

Through any conductor that runs from outside the building to the device. NIST's surge guide lists the paths as "power, telephone, cable, or antennas" and warns that equipment connected to two systems at once, such as a computer on both power and a network line, can be damaged by the voltage difference between them.

NIST's Surges Happen! (SP 960-6, May 2001) was written for homes, but the physics carries straight into a dental office. Its key line: "Each of these connections offers a path for a surge to come in, something that might be overlooked when the cause of damage is explained as a 'power surge.'" The guide names two origins, "lightning surges and switching surges", and notes that "A surge will last only a few millionths of one second", which is why nobody in the office sees anything happen.

In a dental office, the paths look like this:

    • The utility feed. Power arrives at the meter and panel and travels on every circuit in the building. A surge here reaches anything plugged into a wall.
    • The internet line. A coaxial cable from the cable company is a copper conductor from outside to your modem. A fiber service usually ends in a terminal (an ONT) that has its own power supply and a copper Ethernet port into your firewall.
    • Phone and analog lines. Copper phone lines still serve fax machines, alarm panels, elevator phones and some card terminals in older Central Florida plazas.
    • Long data runs. Ethernet cable to an outdoor camera, a gate controller, a sign or a detached sterilization or storage building leaves the building and comes back in, carrying whatever it picks up outside.
    • Antennas. A rooftop cellular booster or satellite dish brings a cable down into the building.

The idea that catches most offices out is what NIST calls the two-link appliance: a device connected to both power and a communications line. A surge "coming in from one of the two systems - power or communications - can damage the appliance, because of a difference in the voltage between the two systems when the surge occurs. This can happen even when there are surge protectors on each of the systems." NIST's answer is a protector that "incorporates, in the same package, a combination of input/output connections for the two systems."

Almost everything in a modern dental office is a two-link device. An operatory PC has power and a network cable. A VoIP desk phone takes power and data on the same Ethernet line from a switch that is itself plugged into the wall. An intraoral sensor hangs off a PC that is on the network. That is why the switch can die while the server next to it survives: the surge took the data path, not the power path.

Two more NIST lines matter for the conversation with your electrician. First, "lightning rods are intended to protect the structure of the house and avoid fires. They do not prevent surges from happening in the wiring." Second, "The best surge protector in the world can be useless if grounding is not done properly." Grounding and bonding are the electrician's job, not something staff should touch or an IT provider should improvise.

Which equipment in a dental office is most exposed, and how should each be protected?

The most exposed equipment is whatever connects to a line that leaves the building: the internet terminal, the firewall, the network switch that powers the phones, and anything on long cable runs. Each device needs protection on every path it uses, installed by the trade that owns that path.

Use the table below as an exposure map. Walk the office with it, find each device, and write down what currently protects it. Blank cells are your work list.

EquipmentHow a surge reaches itProtection layer to ask aboutWho installs it
Server or NAS (practice management database, imaging archive)Building power; network ports through the switchLine-interactive UPS with shutdown software; upstream panel protectionIT provider (UPS, shutdown setup); electrician (panel)
Firewall and routerBuilding power; the internet line from the carrierUPS; protection on the incoming data cable before it reaches the firewallIT provider; carrier for its own hand-off
Cable modem or fiber terminal (ONT)Coax from outside; its own power supplyAsk the carrier how its line is protected where it enters; put the terminal's power on the UPSCarrier; electrician for the entry point
Network switch and PoE desk phonesBuilding power; every Ethernet run, including any that leave the buildingUPS for the switch; data-line protection on runs to outdoor devicesIT provider
Wi-Fi access pointsPoE power and data from the switch, often through ceiling runsProtected through the switch and its UPS; separate protection if an access point serves an outdoor areaIT provider
Imaging acquisition PCs and intraoral sensorsBuilding power; network cable; the sensor through the PC's USB portPoint-of-use protection with matching data ports, or a small UPS; follow the imaging manufacturer's installation requirementsIT provider with the imaging vendor
Panoramic or CBCT unitIts own electrical feed; network link to the acquisition PCFollow the manufacturer's installation requirements; no improvised surge stripsEquipment vendor and electrician; IT provider for the network side
Front-desk and operatory PCs, printersBuilding power; network cableCombination power-and-data protector or standby UPS at each workstationIT provider or office, to a written standard
Outdoor cameras, gate and door accessLong cable runs outside the buildingData-line protection where the cable re-enters; controller on UPSSecurity or low-voltage contractor, with the IT provider
Fax, alarm and card terminals on copper linesTelephone pair from outsideTelephone-line protection at the device or entry pointCarrier or alarm company; IT provider confirms what is still on copper

Two notes on the table. First, imaging equipment comes with its own installation requirements from the manufacturer, and those win over any general advice here; the IT provider's job is the computer, the network link and the software side, which is where dental software and imaging support in Orlando comes in. Second, "who installs it" is about trade, not blame. A panel device is electrical work. A UPS with shutdown software is IT work. A camera run is often the security contractor's. If nobody in your office knows which trade did what, that gap is the first thing to close.

Practices running DEXIS, Vatech, Carestream, Planmeca/Romexis or Dolphin Imaging on acquisition PCs, and Dentrix, Eaglesoft, Open Dental or Archy on a local server, have the same pattern: the clinical software is only as available as the PC, switch and server underneath it. The server and workstation side is covered in more depth on our dental server and workstation setup page, and the cabling and switch layout on dental office network design.

Surge protector, UPS or whole-building protection: what's the difference?

They do different jobs. A panel surge protective device diverts large power-line surges before they spread; a point-of-use protector guards one device and its data line; a UPS bridges a sag or short outage and gives the server time to shut down. An office with a server and imaging usually needs all three.

The confusion comes from the products. A power strip with a surge rating, a UPS with surge outlets and a panel device all get called "surge protection". The table separates them by what each does and does not do, using NIST's guide and Schneider Electric's UPS white paper (the manufacturer's own description of UPS types, cited as a source, not as a product recommendation).

LayerWhat it doesWhat it does not doWho installs it
Service-entrance or panel surge protective deviceNIST: its "important function" is "to divert large surges coming on the power line, before they enter the house"It does not protect two-link devices from surges on data lines: NIST answers "No for two-link appliances" when asked whether a service-entrance protector is enoughLicensed electrician
Point-of-use protector with power and data portsLimits a surge at one device, and on combination models carries the data line through the same package (NIST's fix for two-link devices)It keeps nothing running when power drops; quality and condition vary, so ask when it was installedIT provider or office, to a written standard
Standby UPSSchneider Electric: "commonly used to protect individual loads like desktop computers"; the inverter starts when power fails, and it "typically takes almost 10 ms" to switchIt does not condition power continuously; some models add surge suppression and some do notIT provider
Line-interactive UPS"commonly used to protect small quantities of important servers and associated networking equipment"; corrects low or high line voltageIt still has a transfer time when power fails; battery runtime depends on load and battery ageIT provider
Double-conversion (online) UPSPower path does not change on failure, "0 ms transfer time"; "the most popular type above 10 kVA"The white paper places it mainly in larger installations; ask your IT provider whether your closet's load calls for oneIT provider, sometimes with an electrician
Lightning protection system (rods)Protects the structure; NFPA 780 is the standard for installing these systemsNIST: rods "do not prevent surges from happening in the wiring"Specialist contractor

Where the layers meet is where gaps hide. The electrician who fits a panel device may assume the IT provider handles data lines; the IT provider who installs UPS units may assume the panel is protected. A short written note that lists each layer, the date it went in and the trade responsible is worth more than any single product.

Two practical points for an owner. First, a UPS is not a surge protector by default; read its specification or ask your IT provider whether the outlets you are using are surge-protected, battery-backed or both. Second, consumer power strips get swapped, daisy-chained and moved around operatories over time. If a strip has no label, no date and nobody knows where it came from, treat it as unknown and replace it to a standard.

How long should the batteries last, and what should shut down first?

Long enough to ride through flickers and give the server a clean shutdown, not to keep seeing patients through a long outage. NIST describes a UPS as power "across a sag, or for the first portion of an extended outage." Runtime depends on the load and the battery's age, so measure it rather than assume it.

Central Florida's summer pattern is many short events rather than one long one: a flicker as a cell passes, a two-second drop, a minute-long outage while the utility's equipment recloses. A UPS earns its keep on those. It keeps the server, switch and firewall up, so a half-second blip does not reboot the practice management database mid-transaction or drop every phone call at the front desk.

For a longer outage, the goal changes. The server should not run until its battery is flat and then lose power hard. Ask your IT provider to set up the UPS so that, after a set time on battery or at a set charge level, it signals the server to save and shut down by itself. That is what "a clean shutdown" means in practice, and it is the step most often missing in offices that already own a UPS.

The principles for deciding what goes down first, without a fixed script:

    • The server goes down on a signal, not on a person's memory. Shutdown software connected to the UPS handles it whether or not anyone is in the building.
    • Network gear stays up while the server finishes. The switch and firewall are what let the server's final writes, and any alert about the outage, get out.
    • Workstations save and close first. Front-desk and operatory PCs on small UPS units should give staff enough time to save the chart and close the imaging software.
    • Imaging capture is finished or paused safely. Nobody should be cutting power to an acquisition PC while an exposure is in progress; let the procedure reach a safe stopping point.

What to log, so the battery is not a guess:

    • the date each UPS was installed and the date of each battery replacement;
    • the result and date of the last self-test, and the runtime it reported;
    • which devices each UPS feeds (labelled on the unit, not only in someone's head);
    • the replacement interval in the manufacturer's guidance for that model.

A UPS that beeps every morning is not "fine"; it is reporting a failed self-test or a weak battery. Batteries age whether or not the power ever goes out, and Florida closets that run warm in August do them no favours. Decide on replacement with the manufacturer's guidance and your self-test log, not on how long the unit has been quiet.

What do Duke Energy Florida and OUC outages look like for an Orlando practice?

Which utility serves your building decides whom you call, whose updates you watch and what the utility says it will and will not cover. OUC and Duke Energy Florida both publish storm outage figures, and OUC's business guidance puts the job of protecting a customer's own equipment on the customer, not the utility.

Start by checking the practice's power bill. It names the utility for your service address, and that, not a neighbour's account or a map, decides which reporting line and which updates apply to you.

What each utility has published:

    • OUC, Hurricane Milton. OUC's July 1, 2025 reliability release says: "When Hurricane Milton hit Florida in October, more than 89,000 OUC customers lost power," and "crews completely restored electricity within 72 hours."
    • Duke Energy Florida, Hurricane Milton. Duke's October 12, 2024 update reports: "Outages have decreased from over 1 million immediately post-storm to approximately 580,000," and lists Lake, Orange, Osceola and Seminole among the counties that "will be restored by 11:59 p.m. ET on Sunday, Oct. 13." Duke's October 17, 2024 release is headed "Duke Energy Florida restores power for over 99% of customers impacted by Hurricane Milton."
    • OUC on equipment protection. OUC's business power-quality page: "Customers are responsible for properly protecting their electrical equipment because, as infrequent as they are, power interruptions do occur." The same page suggests you "Have a licensed electrical contractor inspect your three-phase equipment and install added protection if needed."
    • Duke on damage at the building. In the same October 17 release, customers "who cannot receive power as a result of damage to the property's meter base, breaker panel or customer-owned electrical wiring should contact their local municipalities for guidance."

The hurricane figures are here because they are what the utilities publish; a summer thunderstorm outage on your block is a smaller event, but the wet season brings that risk back every year. Named-storm planning is a separate job, and Florida's hurricane and cybersecurity guide for dental offices is where it lives on this site.

How to report an outage:

    • OUC lists three channels on its storm center page: "Call our 24-hour reporting line at (407) 423-9018," "Text OUT to 69682 (myOUC)," or log in to myOUC and fill out the outage form.
    • Duke Energy Florida customers should use the outage reporting options on Duke Energy's own website and keep the account number for the practice's service address where the front desk can find it.

Put the right utility's reporting details on the same laminated card as your IT provider's helpdesk number, so whoever is at the front desk at 4 p.m. does not have to search for them.

What should the office do while a storm cell is overhead?

People first. NWS Melbourne's indoor advice is to "Avoid contact with corded phones" and "Avoid contact with electrical equipment or cords," and "If you plan to unplug any electrical equipment, do so before the storm arrives." Leave protected equipment on its UPS, and bring procedures to a safe stopping point before anyone reaches for a plug.

During clinic hours, the useful rules are short:

    • No one crawls under desks pulling plugs while thunder is overhead. That is the moment NWS says to stay away from cords. The protection you installed beforehand is what works during the storm.
    • Leave the server, switch and firewall on their UPS. They are meant to ride through. Pulling them by hand risks the very hard shutdown the UPS exists to prevent.
    • Clinical work reaches a safe stopping point. If power is unstable, the dentist decides when to pause an imaging capture or a procedure. Unplugging chair-side equipment mid-treatment is not a surge plan.
    • One person watches the front desk systems. If phones drop, that person moves to the call-forwarding step in the triage table below.

When a storm is forecast and the office is closing for the day, the guidance changes. FEMA's power-outage sheet says: "Unplug appliances, equipment and electronics to avoid damage from electrical surges. Use surge protection devices." Ready.gov's thunderstorm page (last updated 05/11/2026) adds: "Consider buying surge protectors, lightning rods or a lightning protection system to protect your home, appliances and electronic devices."

For a dental office, that becomes a closing-time decision you agree in advance with your IT provider:

    • workstations, printers and anything not on a UPS can be shut down and unplugged at close;
    • the server, firewall and switch usually stay on their UPS so that overnight backups and monitoring keep running, unless your IT provider advises otherwise for that night;
    • imaging acquisition PCs and sensors follow the imaging manufacturer's guidance.

Write the agreed list down. In the middle of an August afternoon, nobody should be deciding it from memory.

After a strike, how do you find what was damaged?

Work from symptoms to components, check the simple things staff can safely see, and call the IT provider before restarting the server or reinstalling anything. Surge damage is often partial: one port, one power supply, one sensor. A methodical first look saves hours and stops a healthy device from being replaced.

An editorial by Michelle C. Dziurgot in the Journal of the Michigan Dental Association (November 2025) described an August 2025 direct strike whose "all-out power surge" "fried equipment including dental chairs, computers, and HVAC", and advised offices to "Document all damage with photos and receipts." A Dentalcompare clinical director wrote in 2012, after a surge "ended up bouncing half of computers in the office", that "the power supply got fried, and the rest of the machine was fine." Both point the same way: find the failed part before replacing the whole machine, and photograph everything.

Symptom after the stormLikely componentFirst check staff can makeWhen to call the IT provider
No internet anywhere; phones also downCarrier modem or fiber terminal, or the firewallAre the modem or terminal lights on? Is the firewall powered? Check the carrier's outage statusIf the carrier is up and the firewall or modem stays dark
Internet works but every desk phone is deadPoE switch, or the port feeding the phonesAre the switch's lights on? Is its UPS on battery or alarming?Straight away; ask about forwarding the main number to a mobile while the switch is checked
One operatory dark; the rest of the office fineThat PC's power supply, its wall jack, or one switch portDoes the PC show a power light? Try a known-good outlet on the same protectorIf the PC stays dead or boots with no network
Intraoral sensor not detectedThe USB port, the sensor, or its driverTry the sensor in the PC's other USB port, as the imaging vendor's guide allowsBefore reinstalling anything; IT provider and imaging vendor together
Server rebooted mid-dayPower dropped past the UPS, or the UPS failed to transferIs the UPS showing an event or fault? Note the time it happenedBefore anyone reopens the practice management software
UPS beeping steadilyOn battery, overloaded, or a failed batteryIs wall power on in that room? Is the UPS display showing a fault?If it alarms while wall power is on
Wi-Fi gone but wired PCs workAn access point or its PoE portAre the access point's lights on?If more than one access point is dark
Fax, alarm panel or card terminal deadThe copper phone line or the device's line portIs there dial tone on the line?After the carrier or alarm company confirms the line is up
Burning smell, tripped breaker or scorched outletElectrical damageStop; keep people away; do not reset repeatedlyCall a licensed electrician first, then the IT provider

Legend's helpdesk is part of that last column for Legend clients: Helpdesk staffed 24/7 at 1-800-794-1588, alongside 24/7 monitoring, and Legend works with in-house engineers; no outsourced first-level triage. When a part has to be swapped in the building, Legend's model is onsite dispatch by appointment across served dental markets; remote-first nationwide. For phones specifically, our dental phone systems page and the dental helpdesk page describe those services.

Once the office is running again, two follow-ups matter. First, confirm that the last backup completed and can be restored, because a surge that hit the server's power may also have hit its disks; the dental backup and disaster recovery checklist is a good structure for that check. Second, add what failed to a running list. Two storms that each killed the same switch port are telling you where protection is missing.

What does surge and power protection cost, and who pays for what?

Costs follow the trades. Panel protection is quoted by the electrician; UPS units, point-of-use protectors and their setup are hardware and IT work. At Legend, "Hardware procurement, major cabling projects and software licensing are quoted separately." Whether a policy covers surge damage is a question for your insurer and, for the building's wiring, your landlord.

There are no honest universal figures for this. A one-room closet with a server, firewall and switch needs a different UPS from a three-provider office with CBCT and a dozen operatories, and the electrician's quote depends on the panel and building. What an owner can do is get each layer quoted by the right trade, in writing, with the device list attached.

Who usually carries which cost:

    • The practice: UPS units, point-of-use protectors, replacement batteries, and the IT time to install and configure shutdown.
    • The electrician's quote: panel surge protection, and any electrical work the inspection finds.
    • The landlord, depending on the lease: the building's electrical service and panel in many multi-tenant plazas. Read the lease before booking an electrician for a panel you may not own.
    • The utility: OUC's surge protection programs are described as "Designed to protect a renter's or homeowner's electrical appliances and electronic devices", so ask OUC directly before assuming any business coverage. Duke points customers with damage to the meter base, breaker panel or customer-owned wiring to their local municipality.
    • Insurance: ask your insurer what your policy says about surge and lightning damage to equipment and data, and keep the photos and receipts the Michigan editorial recommends.

The data matters as much as the hardware. Replacing a server is a purchase; rebuilding a patient database without a backup is a different problem. Legend's backup is priced separately: "Backup protection from $39.99 per month (storage-dependent)". Our dental backup and recovery page describes the service, and it is the right place to start if the storm left you unsure whether last night's backup ran.

What to ask your IT provider about storms and surges

Put these to the provider you have now, or to any provider you are weighing up. Clear answers include names, dates and a written device list, not reassurance.

Central Florida specifics

  1. Do you know whether our building is served by OUC or Duke Energy Florida, and is that utility's outage reporting number on our office card?
  2. What changes in our IT routine during the wet season, when most of the year's lightning arrives in the afternoons?
  3. Is the coax from the cable company or our fiber terminal protected where it enters, and has the carrier been asked how?
  4. Can you show me the UPS battery log: install dates, last self-test, last replacement and the runtime it reported?
  5. Do you schedule updates and maintenance in the morning or at weekends during the summer storm season?

Protection and responsibility

  1. Which of our devices are two-link (power plus network or phone), and what protects the data side of each?
  2. Which work belongs to our electrician, which to you, and which to the imaging or security vendor, and is that written down?
  3. Is the server set up to shut itself down on a UPS signal, and when was that last tested with the power actually off?
  4. Which outlets on each UPS are battery-backed, which are surge-only, and is each one labelled?
  5. Does anything still run on a copper phone line, such as the fax, alarm or a card terminal?

After a storm

  1. What will you check first after a strike, and what do you want my staff to do before you call back?
  2. How do we forward the main number if the phones fail while the internet stays up?
  3. How do you confirm the backup is good after a power event, and do you send me the result?
  4. Do you keep a list of what failed in each storm, so repeat failures point to missing protection?

Where the facts on this page come from

Every weather, utility and equipment fact above comes from its publisher, quoted or closely paraphrased, with the date the publisher shows: NWS Melbourne's lightning pages (undated; accessed 19 October 2026) and the NWS-hosted 1959–2017 fatality compilation (May 2018); NIST SP 960-6 (May 2001, written for homes); Schneider Electric's UPS white paper (April 2024); FEMA's power-outage sheet (December 2023) and Ready.gov (updated 05/11/2026); OUC's business power-quality page, storm center and July 1, 2025 reliability release; and Duke Energy Florida's October 12 and October 17, 2024 Milton releases. No figure on this page is an estimate of ours. Closer to home, Legend helped create the technology foundation behind Sapphire Dental Studio, which launched in Winter Garden, west of Orlando, with a brand-new facility. For the wider picture of practices across the metro, read our Orlando and Central Florida dental IT guide, and for specialty and provider questions, technology for a pediatric practice in Orlando and a scorecard for choosing a managed IT partner in Orlando.

Questions

Frequently asked questions

Is a power strip enough to protect a dental server?

Usually not. A power strip, even one with a surge rating, protects only the power path, and a server also connects to the network. NIST's surge guide explains that devices linked to power and a communications line can be damaged by the voltage difference between them. A server needs a line-interactive UPS with shutdown software, plus protection upstream at the panel.

Can lightning damage a computer through the internet cable?

Yes. NIST lists telephone, cable and antenna connections alongside power as paths a surge can take into equipment. A coax line from the cable company is copper running from outside to your modem, and the surge can continue through the firewall and switch. Ask the carrier how its line is protected where it enters, and protect the data side.

What kind of UPS does an imaging computer need?

Start with the imaging manufacturer's installation requirements, which take priority. Schneider Electric's white paper describes standby units as common for desktop computers and line-interactive units for servers and networking gear. Your IT provider should match the UPS to the PC's load, confirm the outlets are battery-backed and set the imaging software to close cleanly on a long outage.

How often should UPS batteries be replaced?

Follow the replacement interval in the manufacturer's guidance for that model, and check it against the self-test log rather than the calendar alone. Batteries age even if the power never fails, and warm closets shorten their life. A UPS that beeps or fails its self-test is reporting a problem; replace the battery before the summer storm season starts.

Does the utility pay for equipment damaged by a surge?

Ask your utility and insurer directly. OUC's business guidance places the duty to protect equipment on the customer, and its surge programs are described for renters and homeowners. Duke Energy Florida points customers with damage to the meter base, breaker panel or their own wiring to the local municipality. Keep photos and receipts either way.

When is lightning most likely in Central Florida?

NWS Melbourne's figures put over 90% of the local lightning in the May-to-October season, and in the half of the day from noon to midnight. For a dental office, that puts the risk on summer afternoons, during the busiest clinical blocks. Schedule server updates and maintenance in the mornings in those months, and do battery replacements and electrical work between November and April.

Should we unplug equipment when a storm is forecast?

If the office is closing, FEMA advises unplugging equipment and electronics to avoid surge damage, and NWS Melbourne says to unplug before the storm arrives, not during it. During clinic hours, leave the server, switch and firewall on their UPS. Agree a written closing list with your IT provider so staff know what to unplug and what stays on.

Who installs whole-building surge protection, the electrician or the IT provider?

A licensed electrician installs surge protection at the panel; it is electrical work. The IT provider installs UPS units, sets up automatic server shutdown and protects network and data lines. The imaging vendor sets requirements for its own equipment. Write down which trade owns each layer so nothing falls between them after the next storm.

Our phones died after a storm but the power stayed on. Why?

Desk phones on a VoIP system usually take power and data from a PoE network switch. If a surge came in on a data cable, the switch or one of its ports can fail while wall power is fine, and every phone it feeds goes dark. Check the switch's lights, then call your IT provider and forward the main number meanwhile.

The bottom line

If the last summer storm left you with a dead switch, a sensor that would not connect or a server that rebooted on its own, write down what failed and when, and bring that list to a Free Dental IT Assessment. Legend has served over 3,500 practices since 2004, with 22+ years in dental IT (since 2004), and is headquartered in Dallas. Its Google profile shows a 4.8 rating · 173 Google reviews. Ian Lynch — 22 years in dental IT; oversees the NOC, onsite dispatch and client technology roadmaps. You can see how we support practices across the metro on our Orlando dental IT services page, and when you are ready, request your Free Dental IT Assessment.

Ian Lynch
About the author

Ian Lynch

Operations Lead, Legend Networking

22 years in dental IT. Oversees the NOC, onsite dispatch and client technology roadmaps for practices nationwide.

  • Operations center

    Dallas, Texas

    Serving dental practices nationwide since 2004

  • NOC hours

    24/7 monitoring

    Dental IT help desk Mon–Sat; emergency line always on

  • Engineers

    In-house only

    No outsourced first-level dental IT triage

  • Onsite dispatch

    By appointment

    Technicians deployed across served dental markets

About Legend Networking
Your next step

Next step: bring the list of what failed after the last storm

Tell us what you are running and we will review it with you.

Or call 800-794-1588

Free IT assessment

Tell us what you are running

Your information is secure and will never be shared.